HEX: 07 - Heater lock-out
Fault Details:
Heater lockout.
Recommended Solution:
Reset the heater lockout and try restarting the unit.
Read any additional fault codes and follow the troubleshooting instructions.
To reset the heater lockout:
Turn the heater ON.
Remove fuse F1 for at least 10 seconds.
Turn the heater OFF.
Reinsert fuse F1.
Turn the heater ON again.
NOTE:
This fault has occurred multiple times:
Fault counter: >10 times
Failed start counter: >7 times
Overheat counter: >20 times
Please note that fault code meanings can vary depending on the model and controller type.
If you’re unsure, contact Heatso Support for assistance.