HEX: 07 - Heater lock-out

Fault Details:
Heater lockout.

Recommended Solution:
Reset the heater lockout and try restarting the unit.
Read any additional fault codes and follow the troubleshooting instructions.

To reset the heater lockout:

  1. Turn the heater ON.

  2. Remove fuse F1 for at least 10 seconds.

  3. Turn the heater OFF.

  4. Reinsert fuse F1.

  5. Turn the heater ON again.

NOTE:

This fault has occurred multiple times:

  • Fault counter: >10 times

  • Failed start counter: >7 times

  • Overheat counter: >20 times

Please note that fault code meanings can vary depending on the model and controller type.